Nominal diameter |
63, 100 and 160 mm |
Accuracy |
P2572 (63 mm) : ±1.6 % of full scale P2574 (100 mm) and P2576 (160 mm) : ±0.5 % of full scale ±1.0 % of full scale |
Scale range (MPa, kPa, bar) |
63 mm : -0.1 ~ 0 to 0 ~ 100 MPa 100 and 160 mm : -0.1 ~ 0 to 0 ~ 200 MPa |
Working pressure |
Steady : 75 % of full scale (63 mm) 100 % of full scale (100 and 160 mm) Over range protection : 130 % of full scale |
Working temperature |
Ambient : -40 ~ 65 ℃ -20 ~ 65 ℃ (With glycerin filling) -40 ~ 65 ℃ (With silicone filling) Fluid : Max. 200 ℃ Max. 100 °C (With glycerin filling) Max. 100 ℃ (With silicone filling) |
Degree of protection |
EN60529/IEC529/IP67 |
Temperature effect |
Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.4 % per 10 ℃ of full scale |
Pressure connection |
Stainless steel (316SS) |
Element |
Stainless steel (316SS) 63 mm : <6 MPa : C type bourdon tube ≥6 MPa : Helical type bourdon tube 100 and 160 mm : <10 MPa : C type bourdon tube ≥10 MPa : Helical type bourdon tube |
Case |
Stainless steel (304SS) |
Cover |
Stainless steel (304SS) Bayonet type |
Blowout protection |
Solid front Blow-out back |
Window |
Laminated safety glass |
Movement |
Stainless steel |
Dial |
White aluminium with black graduations |
Pointer |
Black painted aluminium alloy |
Process connection |
63 mm : ⅛", ¼" PT, NPT and PF 100 and 160 mm : ¼", ½", ⅜" PT, NPT and PF |
Certificates |
ATEX Ex II GD c IIc TX Pressure equipment directive (2014/68/EU)-Annex III Module H |
Option |
Zero adjustable pointer (Only available with diameter 100 and 160 mm) Zero adjustment (External) : 100 and 160 mm Pressure connection and element : Monel (Only available with diameter 100 and 160 mm) |
Manufacturer |
|