Nominal diameter |
100 and 150 mm |
Accuracy |
Indicator : ±1.0 % of full scale Alarm setting : ±3.0 % of full scale |
Repeatability |
±1.0 % of adjustable range |
Adjustable range (MPa, kPa, bar) |
-0.1 ~ 0 to -0.1 ~ 2 MPa 0 ~ 0.1 to 0 ~ 35 MPa |
Working temperature |
Ambient : -20 ~ 65 °C Fluid : Max. 100 °C |
Degree of protection |
EN60529/IEC529/IP55 |
Temperature effect |
Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.4 % per 10 ℃ of full scale |
Pressure connection |
Stainless steel (316SS) |
Element |
C type bourdon tube Stainless steel (316SS) |
Case and cover |
ALDC 12.1, silver gray painted for 150 mm ALDC 12.1, black painted for 100 mm |
Contact |
Micro contact type One SPDT or two SPDT |
Contact rating |
150 mm - SPDT contact rating AC 125 V / 250 V, 15 A DC 125 V, 0.4 A for resistance load DC 125V, 0.03 A for inductive load 100 mm - AC 250 V, 3 A / AC 125 V, 5 A DC 250 V, 0.2 A / DC 125 V, 0.4 A DC 30 V, 4 A Dielectric strength : AC 500 V/min |
Conduit connection |
150 mm : ¾" PF 100 mm : M20 x 1.5 |
Process connection |
⅜", ½" PT, NPT and PF |
Certificates |
Pressure equipment directive (2014/68/EU) Annex III Module H |
Manufacturer |
|