P750 series have diaphragm seal to be combined with a pressure gauge. These series are suitable to be used for the situation where corrosive, contaminated, hot, and viscous pressure mediums are present, and it could be used for a chemical, food, beverage, biochemical, and pharmaceutical industry.
Nominal diameter |
63, 80 and 100 mm |
Accuracy |
63 and 80 mm : ±1.6 % of full scale 100 mm : ±1.0 % of full scale |
Pressure range (MPa, kPa, bar) |
Steady : 75 % of full scale (63 and 80 mm) 100 % of full scale (100 mm) Over range protection : 130 % of full scale |
Working pressure |
Steady : 75 % of full scale Over range protection : 130 % of full scale |
Working temperature |
Ambient : -20 ~ 65 °C Fluid : Max. 121 °C |
Temperature effect |
Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale |
Process connection |
316SS P751 : 1½" and 2" Nut P752 : 1", 1½", 2", clamp connection P753 : PF¾", PF1", PF1½", male screw P754 : Standard and non standard flange P755 : Homogenizer P756 : Homogenizer flange (95 x 43 x 28 mm) |
Body |
Stainless steel (316SS) |
Diaphragm |
Stainless steel (316L SS) Electropolished diaphragm Ra 12 ~ 20 ㎛ |
System filling |
Food grade oil (FDA certified) |
Certificates |
ATEX Ex II GD c IIC TX |
Manufacturer |
 |
Datasheet: 
All features and specifications subject to change without notice, delivery subject to availability, correction of errors and omissions excepted.