| Nominal diameter |
50 mm (2") |
| Switch point accuracy |
±2.0 % of full scale |
| Scale range |
0 ~ 28 MPa |
| Working pressure |
Steady pressure : 75 % of full scale value Fluctuating pressure : 67 % of full scale value |
| Working temperature |
Ambient : -20 ~ 65 °C Fluid : Max. 100 °C |
| Temperature effect |
Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.4 % per 10 ℃ of full scale |
| Pressure connection |
Type 316L SS electropolished low mount or center back mount surface finish Ra≤0.25 ㎛ ■ ¼" NPT male thread ■ VCR® male or female face seal fitting |
| Element |
Type 316L SS <6 MPa : C-type bourdon tube ≥6 MPa : Helical type bourdon tube |
| Case |
Type 304SS, Electropolished with pressure relief |
| Cover and window |
Twist-lock polycarbonate |
| Movement |
Stainless steel |
| Pointer |
Black painted aluminium alloy |
| Dial |
White PVC, with pointer stop pin With black/red lettering, dual pressure scale (bar) |
| Helium leak rate |
Tested to confirm leakage rates of less than 10 -9 mbar • ℓ/sec |
| Connection |
26 AWG, PVC 6 feet (2 m) |
| Maximum switching current |
0.5 amps AC/DC noninductive load |
| Maximum power |
10 W/DC, 12 VA/AC |
| Maximum switching voltage |
28 V AC/DC |
| Manufacturer |
 |